Product Identification
Product ID:940911, TISAB III CONCENTRATE WITH CDTA (SUPDAT)
MSDS Date:10/15/1996
FSC:6810
NIIN:00N011456
MSDS Number: CGZNN
Responsible Party
BEVERLY, MA 01915-6199
US
Emergency Phone: 508-922-4400
Info Phone: 508-922-4400
Preparer: FLYNN
Cage: 30260
Contractor
Telephone: 617-242-3900
Cage: 30260
Ingredients
AMMONIUM CHLORIDE (CERCLA)
CAS: 12125-02-9
RTECS: BP4550000
Fraction By Weight: 26%
OSHA PEL 10 MG/M3
ACGIH TLV: 10 MG/M3 FUME
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETIC ACID, AMMONIUM SALT; (AMMONIUM ACETATE) (CERCLA)
CAS: 631-61-8
RTECS: AF3675000
Fraction By Weight: 5%
OSHA PEL N/K
ACGIH TLV: N/K
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
CRESOL RED, SODIUM SALT, INDICATOR GRADE
CAS: 62625-29-0
Fraction By Weight: <1%
OSHA PEL N/K
ACGIH TLV: N/K
TRANS-1,2-DIAMINOCYCLOHEXANE-N,N,N',N'-TETRAACETIC ACID
CAS: 13291-61-7
Fraction By Weight: 2%
OSHA PEL N/K
ACGIH TLV: N/K
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: >66%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION MAY CAUSE NAUSEA,
VOMITING, AND ACIDOSIS. SIGNS & SYMPTOMS OF EXPOSURE: COUGHING,
DYSPNEA, IRRITATION OF UPPER RESPIRATORY TRACT AND STOMACH.
CHRONIC: DIFFICULTY BREATHING WEAKNESS, G ENERALLY LOW HAZARD FOR
SKIN & INHALATION, HOWEVER, REPEATED EXPOSURES MAY CAUSE SKIN
IRRITATION AND (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: BREATHING DIFFICULTIES.
Medical Cond Aggravated by Exposure:RESPIRATORY AND STOMACH AILMENTS.
First Aid
First Aid:EYES: IRRIGATE WITH WATER AT LEAST 15 MINUTES. SKIN: WASH OFF
WITH WATER. INHALATION: FRESH AIR - ARTIFICIAL RESPIRATION IF
NEEDED. INGESTION: DILUTE WITH LARGE AMOUNTS OF WATER AND CONSULT
PHYSICIAN.
Fire Fighting
Extinguishing Media:CO*2, DRY CHEMICAL, ALCOHOL FOAM OR MIST.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:VACUUM AND SET ASIDE FOR WASTE DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP WELL SEALED TO PROTECT PROD
INTEGRITY. AMMOUNIUM ACETATE IS A CERCLA HAZARD & IS SUBJECT TO
SECTION 304 OF SARA TITLE III.
Other Precautions:NO EATING OR DRINKING WHILE WORKING W/THIS PRODUCT.
Exposure Controls
Respiratory Protection:NONE. NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL EXHAUST. CONTROL TO EXPOSURE LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . LAB
COAT.
Work Hygienic Practices:NO EATING OR DRINKING WHILE WORKING WITH THIS
PRODUCT.
Supplemental Safety and Health
MFR TRADE NAME/PART NO: TOTAL IONIC STRENGTH ADJUSTMENT BUFFER. PH:
4.8-5.2 @ 25C.
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:14F,-10C
Spec Gravity:1.20 (H*2O=1)
pH:SUPDAT
Solubility in Water:MISCIBLE
Appearance and Odor:ORANGE LIQUID, SLIGHT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS, HYPOCHLORIC BLEACHES, NH*4, NO*5, KCLO*5.
Stability Condition to Avoid:HEAT OR FLAME.
Hazardous Decomposition Products:EMIS TOXIC FUMES WHEN HEATED TO
DECOMPOSITION.
Disposal
Waste Disposal Methods:DILUTE WITH WATER AND WASH DOWN DRAIN WITH
EXCESS WATER. OBSERVE ALL FEDERAL, STATE, AND LOCAL LAWS WHEN
DISPOSING OF THIS SOLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.